Oil & Gas Applications
花蜜直播app gas turbines have an excellent efficiency and super low NOx emission based on 花蜜直播app's well proven design technology. They are suitable for various applications such as baseload power generation, standby power generation, and mechanical drive.
Power Generation
Product Lineup
Gas Turbine Model | M1A-13/17 | M1T-13 | M7A-03 | L20A | L30A |
---|---|---|---|---|---|
Generator Model | GPB15/17 | GPB30 | GPB80 | GPB180 | GPB300 |
Output Power |
1,510 | 2,850 | 7,410 | 17,970 | 28,450 |
*Normal Rating per ISO at 15ºC(59F)at sea level
No inlet/exhaust losses
Relative humidity 60%
Natural gas (100% CH4, LHV=35.8MJ/Nm3(960Btu/scf))
Diffusion combustor without water injection
GPB15/17
*Normal Rating per ISO at 15ºC(59F)at sea level
No inlet/exhaust losses
Relative humidity 60%
Natural gas (100% CH4, LHV=35.8MJ/Nm3(960Btu/scf))
Diffusion combustor without water injection
Nominal performance at generator terminals (generator efficiency 96.5%)
Specifications | |
---|---|
Oil & Gas Key Feature | Zone 2 Electrical System Integrated Lube Oil System Full 316L Stainless Steel piping 2x100% ventilation fans |
M1A-13 Gas Turbine | Heavy Duty, single shaft 2 stage Centrifugal Compressor Single Can-type Combustor Dry Low Emission (option) Dual Fuel Combustion (option) Alternate Fuel Capability (option) 3 stage Axial Turbine Tilting Pad Journal/Thrust Bearing Casing and Radial Shaft Vibration Transducer |
Reduction Gearbox | Epicyclic Type |
Reduction Gearbox Output Speed | 1,500 rpm for 50 Hz service 1,800 rpm for 60 Hz service |
Alternator | 3 Phase, 4 Wire, Synchronous, Brushless Exciter |
Starter | VFD Motor Start System Pneumatic Start System (option) |
*Approximate Package Dimension (L, W, H) | 6.2 m x 1.85 m x 2.5 m |
*Approximate Package Weight (dry) | 11 ton |
*without Inlet & Ventilation System
GPB30
GPB80
*Normal Rating per ISO at 15ºC(59F)at sea level
Inlet Loss: 0.98kPa, Exhaust Loss: 1.96kPa
Relative humidity 60%
Natural gas (100% CH4, LHV=35.8MJ/Nm3(960Btu/scf))
Diffusion combustor without water injection
Nominal performance at generator terminals (generator efficiency 97.8%)
Specifications | |
---|---|
Oil & Gas Key Feature | Zone 2 Electrical System Integrated Lube Oil System Full 316L Stainless Steel piping |
M7A-03 Gas Turbine | Heavy Duty, single shaft 11 stage Axial Flow Compressor with Variable Vane System 6 Can Combustors Dry Low Emissions (option) Dual Fuel Combustion (option) 4 stage Axial Turbine Tilting Pad Journal/Thrust Bearing Casing and Radial Shaft Vibration Transducer |
Reduction Gearbox | Epicyclic Type |
Reduction Gearbox Output Speed | 1,500 rpm for 50 Hz service 1,800 rpm for 60 Hz service |
Alternator | 3 Phase, 4 Wire, Synchronous, Brushless Exciter |
Starter | VFD Motor Start System |
*Approximate Package Dimension (L, W, H) | 11.9 m x 2.8 m x 3.7 m |
*Approximate Package Weight (dry) | 63 ton |
*without Inlet & Ventilation System
GPB180
L20A Gas Turbine Engine
GPB300
Mechanical Drive
L30A
L30A Gas Turbine Engine
*Normal Rating per ISO at 15ºC(59F)at sea level
No inlet/exhaust losses
Relative humidity 60%
Natural gas (100% CH4, LHV=35.8MJ/Nm3(960Btu/scf))
Diffusion combustor without water injection
Mechanical Drive Performance | |
---|---|
Shaft Output | 30.9MW |
Shaft Efficiency | 41.3% |
Heat Rate | 8,717kJ/kWh |
Turbine Speed Output | 2,800 to 5,880 rpm |
Pressure Ratio | 24.9 |
Exhaust Gas Flow | 88.7kg/s |
Exhaust Gas Temp. | 470 ºC |